| 2 Interface Boards and Options for VLM 200 Series |
| |
| No. |
Item No./Description |
Order Code |
|
|
Interface board IF 1
|
 |
|
|
| 2.1 |
IF 1 with analog output Optically isolated, 4 .. 20 mA (other ranges specified 0 .. 20 mA or 0 .. 24 mA) |
IF 1-AI |
| 2.2 |
IF 1 with RS 232 Optically isolated, can be combined with option IF 1-AI option |
IF 1-RS 232 |
| 2.3 |
IF 1 with RS 422/485 Optically isolated, can be combined with option IF 1-AI option |
IF 1-RS 422 |
| 2.4 |
Interface board IF 2
built in to VLM 200, incl. additional connection socket with plug,
2 programmable optically isolated pulse outputs, each with two phases,
passive NPN transistor, frequency 0.4 Hz-25 kHz, resolution 20 ns)
|
 |
|
IF2 |
| 2.5 |
Interface board IF 2F/422
built in to VLM 200, incl. additional connection socket with plug,
2 programmable optically isolated pulse outputs, each with two phases,
RS422-driver, frequency 0.4 Hz - 500 kHz, resolution 20 ns
|
IF 2F/422 |
| 2.6 |
Interface board IF 2F/5V
(built in to VLM 200, incl. additional connection socket with plug,
2 programmable optically isolated pulse outputs, each with two phases and inverted signals,
5 V driver, frequency 0.4 Hz - 500 kHz, resolution 20 ns
|
 |
|
IF 2F/5V |
| 2.7 |
Option for Interface board IF 2, IF2F
IF2 card with analog output 16 bit as additional component version, optically isolated, 4-20 mA
(please specify other ranges 0-20 mA or 0-24 mA)
|
IF 2/AI |
| 2.8 |
Interface board IF 2/PP
built in to VLM 200, incl. additional connection socket with plug,
2 programmable optically isolated pulse outputs, frequency 0.4 Hz-50 kHz,
7 balanced drivers with +/- 100 mA per output, external power supply +15 to 30 Volt;
A2, /A2, B2, /B2, A3, and B3 pulse outputs and OUT3 status output
|
 |
|
IF 2F/PP |
| 2.9 |
Interface board IFETHER
built in to VLM 200, incl. connection socket with plug with 5 m patch cable RJ45,
output measuring rates over Ethernet, TCP/IP, UDP/IP and Telnet
|
IFETHER |
| 2.10 |
Connection board ABETHER
built in to VLM 200 instead of AB 1, incl. connection socket and 5 m patch cable RJ45
VLM 200 programming over Telnet and output of measuring rates over TCP/IP, UDP/IP and Telnet
(If new device without AB 1 wth extra discount)
|
ABETHER |
| 2.11 |
ECC 2 shaft encoder controller slot card
controller for connection of a encoder, measurement as of 0 m/s, directional
identification from the shaft encoder signal; built in to VLM 200, incl.
additional connection socket with plug
|
 |
|
ECC2 |
| 2.12 |
Option RS 422/485 for ECC 2 shaft encoder controller slot card
ECC 2 with RS 422 / RS 485, optically isolated
|
 |
|
ECC2-RS 422 |
| 2.13 |
Option RS 232 for ECC 2 shaft encoder controller slot card
ECC 2 with RS 232, optically isolated
|
ECC2-RS 232 |
| 2.14 |
Interface board IF-PROFI for Profibus DP
for VLM 200 firmware version 6.7, binary data at the Profibus, different modes, min actualisation time 10 ms,
delivery incl. special connection sockets and two standardised circular connectors
|
 |
|
IFPROFI |
| 2.15 |
Automatic directional detector
built in to VLM 200, retrofit possible, cannot be combined with F- and S-series
|
 |
|
DIR |
| 2.16 |
Real time clock RTC
date and time, built in to VLM 200, retrofit not possible
|
RTC |
| 2.17 |
Power supply 24 Volt / DC
built in to VLM 200, retrofit not possible
|
24DC |
| 2.18 |
Additional connection socket with plug
built in to VLM 200, 5-pole, for device connections 4 and 5, 1-2 pieces are possible
|
CONPG9 |
| 2.19 |
Additional filter board FB1
Please specify velocity ranges, range depends on VLM200 - type and setting of DIRECTION parameter!
|
 |
|
FB1 |
| 2.20 |
PC-Software VLMTOOL
Convenient parameter setting and device administration including graphic online output with protocol,
designed for Windows 98/NT/2000/XP
|
 |
|
VLMTOOL |
Notes: Only one Interface board can be plugged in; for the IF 1 interface card and ECC2 controller slot
card RS 232 option can not be combined with the RS 422 option! An analog output is not available for IF 2/PP!
| |
| 3 Spare Parts for VLM 200 and External LI35 Lighting |
| |
| No. |
Item No./Description |
Order Code |
| 3.1 |
Spare lamp for VLM 200
valid from October 1996
|
 |
|
LM6H10W |
| 3.2 |
Spare lamp for VLM 200
valid until September 1996
|
LB6H10W |
| 3.3 |
Spare lamp for LI 20
|
LM12H20W |
| 3.4 |
Spare lamp for LI 35
|
LS12H35W |
| 3.5 |
Spare window OW 2
for VLM 200 and LI 20
|
 |
|
OW 2 |
| 3.6 |
Spare window OW 3
for VLM 200 H lighting window and LI 35
|
OW 3 |
| 3.7 |
Spare window OW 4
for VLM 200 H lens window
|
OW 4 |
| 3.8 |
External lighting LI 35
IP 65 casing, power supply 230V/AC, 35 W halogen lamp LS12H35W,
incl. mains cable; please order spare lamp LS12H35W / LI 35 at the same time
|
LI 35 |
| No. |
Item No./Description |
Order Code |
| 5.1 |
Comfortable counter/display PAXI
for switchboard mounting; 85-250 V/AC RS 485 and optional RS 232 for display VLM 200 measuring rate,
two switching outputs, display red, programmed for VLM 200 connection
|
 |
|
PAXI / RS485 bzw. PAXI / RS232 |
| 5.2 |
Comfortable Counter/display PAXICA
built in to IP65 steel casing data as PAXI, all connections can be screwed,
incl. all connection cables, short documentation
|
 |
|
PAXICA / RS485 bzw. PAXICA / RS232 |
| 5.5 |
Digital display for analog signals PAXD
for switchboard mounting; 85-250 V/AC; input 0/4 to 20 mA, display red, programmed
for VLM 200 connection (display of measurement rate 0..100 at 4..20 mA analog signal)
|
PAXD |
| 5.6 |
Digital display for analog signals IP65 PAXDCA
built in to IP65 steel case; data as PAXD, all connections can be screwed,
incl. signal connector, power cable and wiring documentation
|
PAXDCA |
| 5.7 |
Analog current meter ACM
aluminum housing, IP52; analogue current meter 4..20 mA, displays 0..100 %, incl. 5 m connection cable
|
 |
|
ACM |
| |
| 6 Mounting Accessories and Protective Equipment |
| |
| No. |
Item No./Description |
Order Code |
| 6.1 |
Mounting plate MP 3
with long holes for z-direction, upgrade to MP 3R possible
|
 |
|
MP 3 |
| 6.2 |
Mounting plate MP 3R
with long holes for z-direction and rotation, incl. MP 3 and rotation plate
|
 |
|
MP 3R |
| 6.3 |
Set of vibration absorbers for VLM 200
4 x M6 hole on M6 thread, incl. 4 x M6 screws, 20 mm higth
|
ELM4 |
| 6.4 |
Air jet unit PA 2
with ¼ ´´ connection thread, protection against dry dust,
mounted on the VLM 200; cannot be combined with LA option; tempered, clean compressed air required
|
 |
|
PA 2 |
| 6.5 |
Linear unit LJ 1b for device adjustment Y-direction or Z-direction
incl. adapter plate for VLM 200, can be used optionally for X-direction, 30 cm procedural distance, other lengths on request |
 |
| LJ 1b |
| 6.6 |
Linear unit LJ 2b for device adjustment Y- and Z-direction
incl. adapter plate for VLM 200, 30 cm procedural distance each, other lengths on request
|
 |
|
LJ 2b |
| 6.8 |
Cooling and protection case CB 5 for VLM 200
for rolling mill applications, cover has all-around seal, high-grade steel/ stainless; tempered,
clean air required, not for L-series, design for 70 mm hose diameter; delivery incl. TB4 or TB5
|
 |
|
CB 5 |
| 6.9 |
Protection nozzle TB 4 for CB 5
Protection against oil, water, dust and steam; tempered, clean air required, high-grade steel/stainless,
please specify the working distance xxx of VLM 200!
|
 |
|
TB 4 / xxx (xxx = 185, 240, 330) |
| 6.10 |
Protection nozzle TB 5 for CB 5
Protection against oil, water and dust; tempered, clean air required, high-grade steel/stainless,
short length, please specify the working distance xxx of VLM 200! |
 |
|
TB 5 / xxx (xxx = 185, 240, 330) |
| 6.11 |
Air supply and connection case AC 5
for CB 5, delivery includes 5 m air hose and cable for VLM 200, design for 70 mm hose diameter
|
 |
|
AC 5 |
| 6.12 |
Air hose, length 5 m, diameter 70 mm
Plastic air hose 70 mm, for connection AC4 to CB4b, delivery incl. customised cables to the VLM 200;
extra charge per meter, until maximum length 15 m
|
ATP 4 / 70 |
| 6.13 |
Metal air hose, length 5 m, diameter 70 mm
Metal air hose 70 mm, for connection AC4 to the CB4b, delivery incl. customised cables to the VLM 200;
extra charge per meter, until maximum length 15 m
|
ATM 4 / 70 |
| 6.14 |
Viton air hose, length 5 m, diameter 70 mm
Viton air hose 70 mm, for connection AC4 to the CB4b, delivery incl. customised cables to the VLM 200;
extra charge per meter, until maximum length 15 m
|
ATV 4 / 70 |
| |
| 8 Cables and Cable Connectors for VLM 200 Series |
| |
| No. |
Item No./Description |
Order Code |
| 8.1 |
Cable for power supply 230V/AC (115 V/AC)
5 m, 3 wires with protection contact
|
POCA-AC / VLM2 |
| 8.2 |
Cable for power supply 24V/DC
5 m, 3 wires one side with open ends
|
PSC-DC / VLM2 |
| 8.3 |
RS 232 cable (programming cable)
screened, 5 m, 3 wires with PC connector for serial interface (D-SUB 9)
|
RSCs / VLM2 |
| 8.4 |
Connection cable for AB ETHER and IF ETHER
CAT 5 with RJ45 connection plug, 5 m
|
CABLE 4Ms-RJ45 |
| 8.5 |
Connection cable for AB ETHER and IF ETHER
CAT 5 with RJ45 connection plug, 10 m
|
CABLE 4Ms-RJ45 -10m |
| 8.6 |
Signal connecting cable with 2 female connectors
screened, 5 m with 2x CON5Fs
|
CABLE 5Fs-5Fs |
| 8.7 |
Signal connecting cable with female connector
one side with open ends, screened, 5 m with 1x CON5Fs
|
CABLE 5Fs-open |
| 8.9 |
Male cable connector for gauge connection 1
screened, standard version (RS232)
|
CON-5Ms |
| 8.10 |
Male angled connector for gauge connection 1
screened, angled, special version (RS232)
|
CON-5MsA |
| 8.12 |
Female cable connector 5 contacts screened
for connection 2, 4 and 5, screened, standard version
|
CON-5Fs |
| 8.13 |
Female angled connector 5 contacts angled
for connection 2, 4 and 5, screened, angled, special version
|
CON-5FsA |
| 8.18 |
Female socked PG9 for signal connection
interference-free, 5 contacts, male, open, for connection 2,4 and 5 (signal)
|
PG9-5M |
| 8.19 |
Female socked PG9 Ethernet
coded, 4 contacts, female, open, for connection AB ETHER and IF ETHER
|
PG9-4F |
| 8.20 |
Male socked PG9 for RS 232
Interference-free, 5 contacts, female, open, for connection 3 (RS232)
|
PG9-5F |
| 8.12 |
Male angled connector 8 contacts
For IF2F/5V connection 5, screened, standard version
|
CON-8Ms |
| 8.13 |
Female cable connector for power supply
for connection 3, 230 V or 115 V, standard version
|
POCO-AC |
| 8.14 |
Female angled connector for power supply
for gauge connection 3, angled, 230 V or 115 V, special version
|
POCOA-AC |
| 8.15 |
Female cable connector for 24 V power supply
for gauge connection 3, standard version
|
POCO-DC |
| 8.16 |
Female angled connector for 24 V power supply
for connection 3, angled, special version
|
POCOA-DC |
| 8.17 |
Profibus Termination Resistor
|
PTX |
| 8.19 |
Male socked PG9 for signal connection
interference-free, 5 contacts, male, open, for connection 2,4 and 5 (signal)
|
PG9-5M / VLM2 |
| 8.19 |
Female socked PG9 for Ethernet/Profibus
B-coded, 4 contacts, male, open, for connection 4 and 5
|
PG9-4F / VLM2 |
| 8.20 |
Female socked PG9 for IF2F/5V
8 contacts, male, open for IF2F/5V, for connection 5
|
PG9-8F / VLM2 |
| 8.21 |
Male socked PG9 for RS 232
Interference-free, 5 contacts, female, open, for connection 3 (RS232)
|
PG9-5F / VLM2 |
| 8.22 |
Male socked 230 or 115V for gauge connection 3
Installation into the gauge
|
POSO-AC / VLM2 |
| 8.23 |
Male socked 24V for gauge connection 3
Installation into the gauge
|
POSO-DC / VLM2 |
Explanation: open, i.e. with end splices
| |
| 9 Installation Accessories and other Equipment |
| |
| No. |
Item No./Description |
Order Code |
| 9.1 |
NF-signal cable 5 wires, price per meter
PUR signal cable, 5x 0,25mm², screened, Ø 5,2 mm
|
PUR5S |
| 9.2 |
NF-signal cable 8 wires, price per meter
PUR signal cable, 8x 0,25mm², screened, Ø 6,2 mm
|
PUR8S |
| 9.3 |
HF-signal cable, price per meter
twisted pair wires, screened, Ø 6,2 mm, recommended for IF 2 F/422 and analogue output
|
HF4S |
| 9.4 |
Resistor 1.2k for rack mounting
|
RH1.2 |
| 9.5 |
Resistor 1.2k with red LED for rack mounting
|
RHLEDr1.2 |
| 9.6 |
Resistor 1.2k with green LED for rack mounting
|
RHLEDg1.2 |
| 9.7 |
Resistor 120 Ohm for rack mounting
recommended for IF 2F/422
|
RH120 |
| 9.8 |
Measurement-resistor 500 Ohm / 0,1%
|
RS500 |
| 9.9 |
Tool for adjustment of working distance for VLM 200 L - series
170 mm aluminum tube
|
WD170 / VLM2 |
| 9.10 |
Tool for adjustment of working distance for VLM 200 A standard - series
185 mm aluminum tube
|
WD185 / VLM2 |
| 9.11 |
Tool for adjustment of working distance for VLM 200 D - series
240 mm aluminum tube
|
WD240 / VLM2 |
| 9.12 |
Tool for adjustment of working distance for VLM 200 H - series
330 mm aluminum tube
|
WD330 / VLM2 |
| 9.13 |
Converter RS 422 to two phases to TTL
for IF2F/422; rack mounting; output signal A, /A, B, /B; 24 Volt power supply; up to 500 kHz, output TTL 5V/24 mA
|
WAN422 |
| 9.14 |
Profibus Gateway Unigate/VLM2
for VLM 200 series, rail mounting, power supply 24 V, RS232/RS485 to Profibus DP, different output modes
|
 |
|
Unigate / VLM2 |
| 9.15 |
Impulse transformer TR1701
for A/B signals up to 200 kHz, 5 or 24 V level input and output, opto isolated, rail mounting, power supply 24 V
|
TR1701 |
| 9.16 |
Pulse divider TR1701/P1
for A/B signals up to 200 kHz, 5 or 24 V level, opto isolated, dividing relation can set to 1 up to 64
|
TR1701/P1 |
| 9.17 |
Gateway RS232-RS422
opto isolated, rail mounting, power supply 24 V
|
CON232/422 |
| 9.18 |
S-Interface for VLM 200 S Series
generation of the synchronization trigger signal for S-Series for difference measurement applications; allows easy connection of 2 up to 3 gauges of the VLM 200 S-Series to a PLC; rail mounting, power supply 24 V
|
S-Interface |
| |
 |
You can find information about the VLM 200 Series on the side Measurement Gauge VLM 200. |
| |
 |
Visit the side VLM 200 Applications. You can download application briefs written in different languages. |
| |
 |
You can find a short overview of the gauges of the VLM 200 Series. You can download Data Sheets. |
| |
 |
You need a sollution for your measurement task? Please contact us: e-mail or phone. |
| |
 |
Do not hesitate to contact us for further information via e-mail or FAX |
| |
 |
Inside the Download Area yon can find the user manual as PDF file.
Or download the Windows-Programme "VLMTERM" (freeware). |
| |
|